138 Chapter 3 
Mode
Adjacent Channel Power—ACP (I&M) Measurement
Mode
Format/BW
Accesses menu keys that enable you to set and define the measurement parameters for the 
ACP measurement. 
When performing an adjacent channel power measurement, you may specify the channel 
standard determined by the modulation type of the signal you are trying to measure 
(CDMA, GSM, etc.). In addition, you may customize the measurement by specifying 
several measurement settings. The measurement settings include bandwidth and 
measurement time for the center channel and the following measurement settings for the 
adjacent channels:
• number of adjacent channels
• offset of the first adjacent channel from the center channel
• offset of the adjacent channels from each other
• measurement bandwidth and measurement time for adjacent channel (one setting for 
all adjacent channels)
These settings determine how the analyzer measures the center channel and its adjacent 
channels. Depending on the modulation type of the signal you are trying to measure 
(CDMA, GSM, etc.), different measurement bandwidths, times, and offsets are required.
Format Type  Sets the method you want to use to determine the measurement parameters.
Default adjacent channel power measurement settings, called ACP formats, are provided 
in the Agilent CSA platforms. Generally, the ACP format is determined by the channel 
standard you select. However, to accommodate your particular situation, you can decouple 
the default formats from the channel standard, or you can change each measurement 
setting independently. The three methods of selecting your measurement settings are:
Chan (Channel): Each channel standard has an associated ACP format. With this method, 
the optimum measurement bandwidth and measurement time for the modulation type are 
automatically selected when you set the channel standard. For example, when you select 
GSM–950 as the channel standard, with this method the analyzer selects the bandwidth 
and time and adjacent channel offsets for the GSM format.
Preset 1
Min 1
Max 4096
Key Path
Meas Setup, Avg Number
Key Path: Meas Setup, Format/BW