Named Pools
Quality of Service Guide 733
create — The create keyword is required if creating a new named pool within the policy when the
system is configured to require the explicit use of the keyword to prevent accidental object
creation. Objects may be accidentally created when this protection is disabled and an object
name is mistyped when attempting to edit the object. This keyword is not required when the
protection is disabled. The keyword is ignored when the named pool already exists within the
policy.
amber-alarm-threshold
Syntax amber-alarm-threshold percentage
no amber-alarm-threshold
Context config>qos>named-pool-policy>q1-pools>pool
Description This command configures the threshold for the amber alarm on the over-subscription allowed.
Users can selectively enable amber or red alarm thresholds. But if both are enabled (non-zero) then the
red alarm threshold must be greater than the amber alarm threshold.
The no form of the command reverts to the default value.
Default 0
Parameters percentage — Specifies the amber alarm threshold.
Values 1 to 1000
red-alarm-threshold
Syntax red-alarm-threshold percentage
no red-alarm-threshold
Context config>qos>named-pool-policy>q1-pools>pool
Description This command configures the threshold for the red alarm on the over-subscription allowed.
Users can selectively enable amber or red alarm thresholds. But if both are enabled (non-zero) then the
red alarm threshold must be greater than the amber alarm threshold.
The no form of the command reverts to the default value.
Default 0
Parameters percentage — Specifies the amber alarm threshold.
Values 1 to 1000