QoS in MC-MLPPP
Quality of Service Guide 843
Description This command configures the value of the MLPPP bundle ingress per class reassembly timer for this
profile.
Parameters timeout-value — Specifies a a reassembly timeout for this policy.
Values 1 to 1000 in milliseconds
description
Syntax description description-string
no description
Context config>qos>mlppp-profile-ingress
config>qos>mlppp-profile-egress
Description This command creates a text description stored in the configuration file for a configuration context.
The description command associates a text string with a configuration context to help identify the
context in the configuration file.
The no form of this command removes any description string from the context.
Default No description is associated with the configuration context.
Parameters description-string — A text string describing the entity. Allowed values are any string up to 80
characters long composed of printable, 7-bit ASCII characters excluding double quotes. If the
string contains special characters (#, $, spaces, etc.), the entire string must be enclosed within
double quotes.
mlppp-profile-egress
Syntax [no] mlppp-profile-egress profile-id [create]
Context config>qos
Description This command creates a profile for the user to configure the egress QoS parameters of a multiclass
MLPPP bundle.
A maximum of 128 egress QoS profiles can be created on the system.
The no form of this command deletes the profile.
Parameters profile-id — Specifies an ingress mlppp-profile ID.