Rockwell Automation Publication 2711P-UM007D-EN-P - December 2015 135
Update Firmware Chapter 6
6. Follow these steps from this dialog box.
.
a. Browse to the location of the firmware source files on your computer,
where the FUP was installed.
The default location is shown.
b. Choose the version of the upgrade firmware from the pull-down
menu.
c. Click Next.
It can take several seconds for the next dialog box to appear while the
FUP is being retrieved.
7. From this dialog box, optionally select the KEPServer drivers that you
want included in the firmware, then click Next.
Kepware drivers are already installed on the PanelView Plus 7 Standard
terminals.