Heating Indicator Decimal Point Enable
(Heat Models) Ht dP
This option allows the owner to enable or disable the heating in-
dicator decimal point on the machine. If enabled, the left most
decimal point on the display will be lit anytime the heater is on
during a cycle.
1. Control must be in Manual Mode. Refer to Entering the Man-
ual Mode.
2. Press the Delicates Bulky () or the Cold () keypad until
Prog appears in the display. Press the START (enter) keypad
and AtS 1 will appear in the display.
3. Press the Delicates Bulky () or the Cold () keypad to scroll
through the programmable options until Ht dP appears in the
display.
4.
When Ht dP appears in the display, press the START (enter)
keypad. The current status will appear in the display.
on = Option Enabled
oFF = Option Disabled
NOTE: To go back to the current programmable op-
tion without changing the value of the active digit,
press the Warm (<) keypad.
5. Press the Delicates Bulky () or the Cold () keypad to
change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Temperature Display Enable (Heat Mod-
els) tP diS
This option allows the owner to program the temperature display.
If enabled, the user can display the water temperature reading
during an agitate or soak step by pressing the active cycle key-
pad. Further presses will toggle the display and the display will
also be exited upon exit of the step.
1. Control must be in Manual Mode. Refer to Entering the Man-
ual Mode.
2. Press the Delicates Bulky () or the Cold () keypad until
Prog appears in the display. Press the START (enter) keypad
and AtS 1 will appear in the display.
3. Press the Delicates Bulky () or the Cold () keypad to scroll
through the programmable options until tP diS appears in
the display.
4.
When tP diS appears in the display, press the START (en-
ter) keypad. The current Temperature Display status will ap-
pear in the display.
on = Option Enabled
oFF = Option Disabled
NOTE: To go back to the current programmable op-
tion without changing the value of the active digit,
press the Warm (<) keypad.
5. Press the Delicates Bulky () or the Cold () keypad to
change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.