Control Identification
Select Cycle Keypads
(Refer to Figure 2 )
Select Cycle keypads are used to select the specific machine cy-
cle. These keypads include Normal, Permanent Press, Delicates
Bulky, and allow the user to select a cycle other than the default
cycle ( Normal Cold). The Select Cycle keypads are not active af-
ter the first Fill Step of the cycle. The selected cycle is indicated
by the light (LED) on the keypad. Pressing the flashing START
(enter) keypad will confirm the selection and the cycle will begin.
When the card reader is used, pressing the START (enter) keypad
will start the cycle and deduct the vend price from the card.
Select Wash Temp Keypads
(Refer to Figure 2 )
Select Wash Temp keypads are used to select the temperature of
the water used for the wash fill. These keypads include Hot,
Warm, and Cold. These pads allow the user to select a water tem-
perature other than the default setting ( Cold).
Select Cycle Modifier Keypads
(Refer to Figure 2 )
The Cycle Modifier keypads are used to select cycle modifier op-
tions. The Regular option is the default and indicates no cycle
modifiers are active. The Deluxe and Ultra options can be pro-
grammed to offer extra features for an added vend price. Features
available include an added prewash, extra wash time, an added
extra rinse, extra rinse time and a warm rinse temperature.
Control Identification
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
17 Part No. F8615401ENR4