Entering the Manual Mode
For programming, testing, and retrieving information from the
control, it is often necessary to enter the Manual Mode by follow-
ing the steps below.
For an overview the Manual Mode, refer to Manual Program-
ming Navigation .
How to Enter Manual Programming
Mode
1. If accessing Diagnostic Tests, be sure the machine is in the
Ready Mode. If the machine is in an active cycle, rapid ad-
vance through the cycle. Refer to the Rapid Advance Feature.
If coins or a card has been entered, refer to Clear Vend Fea-
ture.
2. Open the top cover. Refer to Opening the Top Cover.
NOTE: The coin vault switch must be closed to en-
ter Manual Mode.
3. Press the Regular and Normal keypads at the same time.
4.
The display will show rAPid.
5. Press the Delicates Bulky () or the Cold () keypad to scroll
through the options until the desired option appears in the dis-
play.
6. Press the START (enter) keypad.
NOTE: After entering Manual Mode, if no keypads
are pressed for 4.25 minutes, the control will return
to the previous mode of operation.
How to Exit Manual Mode
Press the Warm (<) keypad until the control returns to the mode
that was active before Manual Mode was entered.
Manual Mode Navigation
Manual Mode is broken into three (3) groups: Manual Program-
ming, Manual Rapid Advance and Manual Diagnostics. Manual
Programming has three (3) subsets: Manual Programming, Man-
ual Read Audit and Manual Reset. Manual Programming can on-
ly be turned on or off with an external device (refer to Communi-
cations). Manual Rapid Advance and Manual Diagnostics can be
turned on and off using an external device or by manual program-
ming (refer to Manual Rapid Advance (Enable/Disable) rAEn
and Manual Diagnostics (Enable/Disable) dAEn of Programming
Control).
By default, all groups are turned on.
The manual features available in each group are as follows (the
menu displayed on the display in this mode is in parentheses).
Manual Programming
Manual Programming (Prog)
Manual Read Audit (AUdit)
Manual Reset (rESEt)
Manual Rapid Advance
Rapid Advance (rAPid)
Manual Diagnostics
Manual Diagnostic Tests (diAg)
If a group is turned off, the display will change from the selected
feature to oFF when the START (enter) keypad is pressed and an
audio signal will sound for one (1) second. The display will then
return to the selected feature. The features in the group cannot be
entered.
Entering the Manual Mode
©