Network Node Number nodE
This option allows the owner to program a unique number used
for wired or wireless communication. Every machine on the same
network must have a different node number to work correctly.
1. Control must be in Manual Mode. Refer to Entering the Man-
ual Mode.
2. Press the Delicates Bulky (∧) or the Cold (∨) keypad until
Prog appears in the display. Press the START (enter) keypad
and AtS 1 will appear in the display.
3. Press the Delicates Bulky (∧) or the Cold (∨) keypad to scroll
through the programmable options until nodE appears in the
display.
NOTE: To go back to the current programmable op-
tion without changing the value of the active digit,
press the Warm (<) keypad.
4.
When nodE appears in the display, press the START (enter)
keypad. The current Network Node Number status will appear
in the display.
5. Press the Delicates Bulky (∧) or the Cold (∨) keypad to
change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Error Programming Error-
This option allows the owner to turn on or turn off certain errors
in the control.
1. Control must be in Manual Mode. Refer to Entering the Man-
ual Mode.
2. Press the Delicates Bulky (∧) or the Cold (∨) keypad until
Prog appears in the display. Press the START (enter) keypad
and AtS 1 will appear in the display.
3. Press the Delicates Bulky (∧) or the Cold (∨) keypad to scroll
through the programmable options until Error- appears in
the display.
4.
When Error- appears in the display, press the START (en-
ter) keypad. Refer to Table 6 for a list of programmable error
code parameters.
5. Press the Delicates Bulky (∧) or the Cold (∨) keypad to select
the desired option.
6. Press the Delicates Bulky (∧) or the Cold (∨) keypad to select
error code.
7. Press the START (enter) keypad when the correct code ap-
pears in the display. The current status will appear in the dis-
play.
NOTE: Press the Delicates Bulky (∧) or the Cold (∨)
keypad and then the START (enter) keypad again to
choose a specific error perimeter. Refer to Table 6 .
8. Press the Delicates Bulky (∧) or the Cold (∨) keypad to
change the status.
NOTE: To go back to the current programmable op-
tion without changing the value of the active digit,
press the Warm (<) keypad.
9. Press the START (enter) keypad when the correct status ap-
pears in the display. The next Error Code Programming op-
tion will appear in the display.
Programming Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
56 Part No. F8615401ENR4