Option Number Option Display Description Factory Default* Value Range
h
E oP
Open Thermistor Sensor
Error Display (Heat
Models)
on on/oFF
i
E SH
Shortened Thermistor
Sensor Error Display
(Heat Models)
on on/oFF
j
EStH
Slow to Heat Error (Heat
Models)
0 (off) 0-255
k
E Ht-
Heat Error Display (Heat
Models)
— —
(1)
E Ht1
Heat Error
oFF on/oFF
(2)
E Ht2
Heat Error Time 120 0-255
l
E Ub
Non-Fatal Unbalance Er-
ror
oFF on/oFF
m
E SL
Suds Lock Error Display
oFF on/oFF
n
SUd-
Suds Removal Routine
Menu
— —
(1)
SUd 1
Suds Removal Routine
Display
oFF on/oFF
(2)
SUd 2
Suds Removal Routines
Allowed Per Cycle
1 0-10
(3)
SUd 3
Suds Removal Routine
Extra Time
on on/oFF
o
ovrFLd
Overflow Mode Display
on on/oFF
p
CLrErr
Allow Error Clearing
on on/oFF
23
tP F C
Temperature Fahrenheit/
Celsius (Heat Models)
FAHrEn FAHrEn/CELCiU
24
FL Hot
Hot Water Temperature
(Heat Models)
140°F [60°C] 35-194°F [2-90°C]
25
FL HC
Warm Water Tempera-
ture (Heat Models)
104°F [40°C] 35-194°F [2-90°C]
26
FL CLd
Cold Water Temperature
(Heat Models)
35°F [2°C] 35-194°F [2-90°C]
27
CooLdn
Cool Down Water Tem-
perature (Heat Models)
140°F [60°C] 50-194°F [10-90°C]
28
FL Lo
Low Water Level 15 1-30
29
FL NEd
Medium Water Level 20 1-30
30
FL Hi
High Water Level 25 1-30
Table 1 continues...
Programming Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
31 Part No. F8615401ENR4