Programming the Cool Down Step Type
The Cool Down Step Type allows the owner to program a soak
step in a cycle. The Cool Down Step Type is identical to the Agi-
tate Step Type except that it allows hours and minutes to be pro-
grammed rather than minutes and seconds. After selecting the de-
sired Cycle Step number and pressing START (enter), XXCLdn
will appear in the display. Press the Delicates Bulky () or the
Cold () keypad to scroll through the options and START (enter)
to select a value.
NOTE: To go back to the current programmable option
without changing the value of the active digit, press the
Warm (<) keypad.
Step
Type
Display
A Display B Values Description
XXCLdn Cool Down Step Type (XX is step number, step type is
flashing)
En diS XXCL01 EnAbLe/diSAbL/dNod 1/
dNod 2
Step Enable/Disable
Choosing dNod 1 and dNod 2 will enable the step
if the cycle modifier is chosen and set to be enabled
in Cycle Modifier Programming Menu CNP-.
StAtUS XXCL02 PrEWSH/WASH/rinSE1/
rinSE2/rinSE3/rinSE4/
SPin
Status LED: The corresponding LED on the control
will be lit during this step.
W tENP XXCL03 g CooL /
Cool Down Temperature (refer to Heating/Cool Down
Display Sequence (Heat Models))
tyPE XXCL04 PLU Co/No Wri
Plumbing Code/Wrinkle
rAtE XXCL05
no/ 0.5 - 12.5°F/Minute [0.3
- 6.9°C/Minute]
Cooldown Rate
rotAtE XXCL06
3-255 Motor On Time (seconds)
PAUSE XXCL07
3-255 Motor Off Time (seconds)
SPEEd XXCL08 no rot/LoW Ag/rEg Ag/
10-50 RPM (X.XX-X.XX G
Force)
Rotation Speed: no rotation, low agitate speed, regu-
lar agitate speed or custom speed in RPM/G Force
0.03-0.75 for 20 pound
0.04-0.86 for 30 pound
0.04-0.94 for 40 pound
0.05-1.07 for 60 pound
0.06-1.27 for 80 pound
0.06-1.27 for 100 pound
rEvErS XXCL09 rEv on/no rEv
Reversing
v tENP XXCL10 CoLd/WArN/Hot
Water Valve Temperature: Cold (cold valve), Warm
(cold and warm valves), Hot (hot valves)
FiLL XXCL11 on/oFF
Fill Valves
Fi tUb XXCL12 on/oFF
Tub Fill Valves (if so equipped)
SPrAY XXCL13 on/oFF
Spray Valves (if so equipped)
C HArd XXCL14 on/oFF
Cold Hard Fill Valve (if so equipped)
AUX FL XXCL15 on/oFF
Auxiliary Fill Valve (if so equipped)
Table 21  continues...
Programming Control
©