CHAPTER 5: MAINTENANCE
LW500A/LW600A PULSED Nd:YAG LASER
5-8 990-539
Section III. Routine Maintenance Schedule
To ensure reliable and safe operation of the Laser, you should regularly perform routine inspection,
cleaning, and maintenance as indicated in the table below.
Action
Frequency or Occasion
Reference Paragraph
Daily
Semi-
Annually
Other
Air Filter Procedures
Inspect air filter
As required when inspected Cleaning the Air Filter
Vacuum air filter
As required when inspected Cleaning the Air Filter
Clean air filter with detergent
As required Cleaning the Air Filter
Cooling Water Procedures
Inspect cooling water level
As required when inspected
Checking Water Level
and Adding Water
Add cooling water
As required when inspected
Checking Water Level
and Adding Water
Partially drain secondary cooling
water
Replacement of ion
exchange resin or cartridge,
water filter replacement,
long-term storage; shipment
Draining the Secondary
Cooling Water
Completely drain primary and
secondary cooling water
Long periods of non-use,
possibility of freezing.
Draining Primary
Cooling Water
Draining Secondary
Cooling Water
Partially drain Primary Cooling
Water
Clean Solenoid Valve
Strainer
Draining the Primary
Cooling Water
Replace Ion exchange cartridge
When necessary
(Roughly every 3 years)
Refilling Ion Exchange
Resin and replacing Ion-
Exchanger
Replace ion-exchange resin
When necessary
(Roughly every 6 months)
Refilling Ion Exchange
Resin and replacing Ion-
Exchanger
Lithium Battery Procedure
Replace lithium battery (BIOS
program storage battery)
Every 30 months
(2-1/2 years)
Replacing Back-up
Battery

Table of Contents