Cirrus 3/4/6000 DB2034 08.04
5.2 Setting the seed level sensor
The level for the filling level sensor can only be
adjusted when the seed hopper is empty:
- Stop tractor engine, apply parking brake and
remove ignition key.
- Use the stair steps (Fig. 84) to climb into the seed
hopper.
Fig. 84
- Open the sieve (Fig. 85).
Fig. 85
- Slacken thumb nut (Fig. 86/2).
- Adjust the level of the filling level sensor (Fig. 86/1)
according to the desired residual amount of seed.
triggers the alarm when the filling
level sensor is not covered with seed any more.
- Tighten thumb nut (Fig. 86/2) .
Only for machines with a working width larger than 4 m:
- Repeat the adjustment on the second filling level
sensor.
Affix both filling level sensor at the same height
inside the seed hopper.
Fig. 86