Settings
60
Cirrus 3/4/6000 DB2034 08.04
5.3.1 Proportional seed rate change during operation
Proportional seed rate change during operation:
- Page 1 (Fig. 89)open in the menu machine data.
- Input of quantity step as % (value for the
proportional seed rate change during operation with
, ).
- By pressing key reset the seed rate change
back to 100%.
Fig. 89
5.4 Calibration test
With the calibration test the coincidence of the pre-set and the actual seed rate is
checked.
Always carry out a calibration test
• when changing the seed type
• in cases with the same seed type, however, with different grain shape, grain size,
bulk density and or different dressing
• after having changed the metering wheels
• in cases of a deviation between the seed rate determined by
and the quantity of seed applied in the field.
Caution
Before commencing the calibration test
• Stop tractor engine
• Remove ignition key
5.4.1 Calibration test on Cirrus with Vario gearbox with seed rate remote control
Calibration test on the Cirrus with Vario gearbox with
seed rate remote control:
- Fill the seed hopper up to min. 1/3 of its volume with
seed (correspondingly less for fine seeds at fine
seeds.
- Take the seed collecting trays off the transport
retainer on the rear side of the hopper.
For transport the seed collecting trays are fitted into
each other and secured with a lynch pin (Fig. 90/1)
on the rear side of the seed hopper.
Fig. 90