User manual Assembly, Installation, Start Up
The battery GEB 5000 / GEB 5010 can be
exchanged without the entire system being
completely disassembled.
Proceed as follows:
■
Switch off the power at the main switch (1).
■
Disconnect the power cable from the
scanner.
■
Disconnect cable (2) from the TGS FX.
■
Release the bolts (3).
■
Remove the battery GEB 5000 / GEB 5010
by tipping it forward.(4)
■
Follow the procedure in reverse for the
reassembly.
Please see Section 5.10, “Battery charging” on page 78 for information about charging the
battery module GEB 5000 / GEB 5010.
4.9 Connection schemes
Following sketches show the cabling with different configurations.
4.9.1 GRP Relative / GRP 1000
© Amberg Technologies AG, 2023 Page 51 of 114