User manual Technical data
Operating environment -20°C to +71°C (case temperature)
Storage environment -40°C to +71°C
Shock 20g (± 2g) / 20ms
40g (± 2g) / 15ms
Standard Random Vibration 2.0g RMS 0.0032 g²/Hz,10 to 980 Hz 0.000085 g²/Hz @
2000 Hz during operation, up to 4.1g RMS if vibration load
is higher
Robust Random Vibration Non-operational 5.8g RMS
11.6 Control computer
The technical data of the control computer can be found in the respective manual.
11.7 Cables
Depending on the configuration, various cables are needed for the GRP System FX. The table
below shows the available cables and the system configurations and where they are used.
Art. No. Description Cable
length [m]
GRP 1000 GRP 3000 GRP 5000
10771 TAC
27/28/29:
TGS FX -
TCPS27/28/29/30
Adaptor
cable
0.32 X X X
10413 TCC 100:
Profiler FX
- TGS FX
cable
0.3 X
10431 USB: TGS
- PC USB
Cable
2.0 X X X
10432 PWC
GEBP500X:
Power Cable
GEB 5000 to
Profiler 500X
1.0 X
20948 PWC
GEBP500X:
Power Cable
GEB 5010 to
Profiler 500X
1.0 X
20769 PWC
GEBP601X:
Power Cable
GEB 5010 to
Profiler 6012
0.6 X
© Amberg Technologies AG, 2023 Page 97 of 114