User manual Technical data
11.3 Profiler FX
11.3.1 General
Construction solid light metal chassis and casing
Protection against dust and water spray, IP 65
Weight 4.280 kg
Size 365 x 100 x 240 mm
Operating environment -10 °C to 50 °C, 80 % relative humidity, non condensing,
elevation up to 4000 metres
Storage environment -25 °C to 70 °C, 85 % relative humidity, non-condensing
Angle resolution 320'000 pulses per 360°, incremental
Min. servo increment 320'000 pulses / 360°
Measurement domain full 360°
Power supply 12 V DC (±10 %) / max. 2 A, on average < 0.6 A
Measurement units 400 gon, 360° decimal, 360° sexagesimal, 2xPI radian
Display 128 x 64 pixel, graphics capability, automatic temperature
compensation
Keyboard 7 rubber buttons with discrete pressure points for comfortable
operation
Servo dial self-resetting, for servomotor driven guidance of vertical axis.
11.3.2 DISTO DEN-10-500
Typical measuring accuracy ±1 mm
Typical repeatability ±0.3 mm
Measuring range on natural
surfaces
0.05 to ~100 m
Measuring range on reflecting
target plate
~0.5 to 500 m
Diameter laser dot 5 m: 4 mm
10 m: 8 mm
50 m: approx. 28 mm x 14mm
Time for measurement 0.04 sec to approx. 3 sec*
Power Supply DC 9 V ... 30 V
Power Consumption 0.15 A @ 24 VDC
Protection against ingress of dust and water spray, IP 65
Temperature range Operation Single measurement: -10° C to 50° C
Operation Continuous measurements -10° C to 45° C
Storage: -40° C to 70° C
* The Measuring time depends on the surface of the target and can last up to 3 seconds.
11.3.3 Transport case
© Amberg Technologies AG, 2023 Page 95 of 114