Technical data User manual
Construction solid light metal housing
Protection against dust and water spray, IP 54
Weight [kg] 1.0
Size [cm] 12.5 x 8.3 x 6.5
Capacity [Ah] at 14.4 VDC 6.5
Operating environment -20°C to 60°C, 80% relative humidity, non condensing,
elevation up to 4000 metres
Charging environment 0°C to 40°C, 80% relative humidity, non condensing,
elevation up to 4000 metres
Storage environment -20°C to 50°C, 85% relative humidity, non-condensing, we
recommend charging of battery every 3-6 month to avoid
deep discharging
11.2.2 Battery column GBC 3010 with battery module GEB 3010
Construction solid light metal chassis and casing
Protection against dust and water spray, IP 54
Weight [kg] Battery module GEB 3010: 3.30
Battery column GBC 3010: 3.33
Size [m] 0.19 x 0.11 x 0.31
Capacity [Ah] at 14.4 VDC 31.9
Operating environment -20°C to 60°C, 80% relative humidity, non condensing,
elevation up to 4000 metres
Charging environment 0°C to 40°C, 80% relative humidity, non condensing,
elevation up to 4000 metres
Storage environment -20°C to 50°C, 85% relative humidity, non-condensing, we
recommend charging of battery every 3-6 month to avoid
deep discharging
11.2.3 Battery column GBC 5000 with battery module GEB 5000 / GEB 5010
Construction solid light metal chassis and casing
Protection against dust and water spray, IP 54
Weight [kg] Battery module GEB 5000: 14.5 / GEB 5010: 6.5
Battery column GBC 5000: 4.65
Size [m] 0.19 x 0.11 x 0.53
Capacity [Ah] at 24VDC GEB 5000: 17 Ah
GEB 5010: 40 Ah
Operating environment -10°C to 50°C, 80% relative humidity, non condensing,
elevation up to 4000 metres
Charging environment 0°C to 45°C, 80% relative humidity, non condensing, elevation
up to 4000 metres
Storage environment -20°C to 50°C, 85% relative humidity, non-condensing, we
recommend charging of battery every 3-6 month to avoid deep
discharging
Page 94 of 114 © Amberg Technologies AG, 2023