Chapter 7 Troubleshooting
The summary below lists some of the most common errors that have been observed during
operation of the components of the Profiler FX system.
In case a function does not perform as expected, or does not work at all, please also refer to
relevant sections of the measurement software manual and the manuals for the field calculator,
as appropriate.
For every malfunction, first check:
Cable connections Profiler FX - TGS FX
Power supply battery power (voltage)
Malfunction Possible cause / perform check
instrument cannot be switched on
battery cable not connected
battery voltage too low
battery fuse blown
no initialising motion on switching on
endless clockwise initialising movement
after switching on
switch off instrument, wait for 10 seconds,
switch on again
repeat 2-3 times if necessary
battery voltage too low
instrument switches off automatically on
attempting to switch on EDM (electronic
distance measurement) or to measure a
distance
battery voltage or power insufficient
EDM module does not come to a halt in
horizontal position after initialising motion.
measured profiles are recorded in a
rotated position
Profiler FX must be checked and adjusted.
Contact your local agency
no distance measurements are recorded
try to measure on another surface
error impossible to resolve
contact your local agency