A-36
M370430-01 Rev B
SCPI Command Reference
Table A-12 Auto Sequence Commandas (Continued)
Function
SCPI Command
Description
Parameter and Range
Query
Begin
Recording
Auto Sequence
Program
[:]PROGram[<channel>][:RECord]:STARt
Start recording new
sequence (overwrites old
sequence).
N/A
Stop
Recording
Auto Sequence
Program
[:]PROGram[<channel>][:RECord]:STOP
Stop recording the auto
sequence program.
(Sequence ready to run.)
N/A
Set the
Program
Command
Execution
Delay Time
[:]PROGram[<channel>][:STEP]:DWEL1
Sets the amount of time to
delay between commands
in a Sequence.
?|<Dwell time in
seconds>
Yes
Read the
current
contents of the
Autosequence
programming
buffer.
[:]PROGram[<channel>]:READback?
Read the current contents
of the Autosequence
programming buffer.
?
Yes