EasyManua.ls Logo

Ametek Sorensen XG - Page 339

Ametek Sorensen XG
381 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M370430-01 Rev B
A-35
A
SCPI Command Reference
Table A-10 Status Commands (Continued)
Service
Request
Enable
(*SRE,*SRE
?)
[:]STATus[<channel>]:SREQuest:ENABle
Access Service Request
Enable Command.
?|<Enable Flags - (0
255)>
Yes
[:]STATus[<channel>]:CLEar
Clears all the Status Data
Structures.
Table A-11 Protection Commands
Function
SCPI Command
Description
Parameter and
Range
Query
Enable the
interlock
functionality.
[:]SENSe[<channel>]:PROTection:INTerlo
ck[:STATe]
Control the Enable/Disable
state of the Interlock System.
?|ON|OFF
Yes
Table A-12 Auto Sequence Commands
Function
SCPI Command
Description
Parameter and Range
Query
Delete all
sequences.
[:]PROGram[<channel>]:DELete:ALL
Erases the sequence
currently in memory.
N/A
Change Auto
Sequence
operating state.
[:]PROGram[<channel>]:STATe
Access to the run state of
the Sequence.
?|RUN|STOP|PAUSE
Yes
Program
selected
sequence end
action.
[:]PROGram[<channel>]:REPeaT
Sets the number of times to
repeat the sequence.
?|<Repeat count (1
65534)>INFinity
Yes

Table of Contents

Related product manuals