314 ARR1575
557D062
557D063
557D064
557D065
18 Troubleshooting
Checking the control piston movement e.g. by means of
ascrewdriver.
Press the piston to the stop from the left to the right three to
four times.
The movement must not be sti in any case!
It must move smoothly and return easily to the zero posi-
tion under the force of the spring, from both sides.
If the control piston does not move smoothly after sev-
eral movements, or it does not spontaneously return to
the zero position, it is mechanically damaged.
The servo block must be repaired in a professional
workshop.
A view of the pump before assembly.
Check the magnetic valve seals for damage.
Lubricate them slightly with oil.