2. In this web browser, type in the VIO 4K virtual IP address (available from the CONTROL > USB
Device menu).
The Web RCS interface should load into your web browser.
W7/W8/W8.1/W10 USERS
(1) Enable the mass storage USB device connection:
1. Go to the CONTROL > USB Device menu on the front panel interface.
2. Select Connection Mode > MASS STORAGE to enable the mass storage device mode connection.
(2) Connect your computer to the VIO 4K:
1. Plug-in the USB type B connector to the front panel USB device port.
2. Plug-in the USB type A connector to your computer USB port.
(3) Install the driver:
1. Open the VIO 4K_USB driver.
2. Go to the Drivers/Windows folder and select your platform.
3. Double-click on AW_VIO4K_Driver_EtherOverUSB.exe to start the driver installation.
4. Accept to install a Network Card type driver if asked during the installation.
(4) Enable the Ethernet over USB device connection:
1. Go to the CONTROL > USB Device menu on the front panel interface.
2. Select Connection Mode > ETHERNET to enabled the Ethernet over USB connection.
(5) Connect to the Web RCS:
1. Open a web browser.
2. In this web browser, type in the VIO 4K virtual IP address (available from the CONTROL > USB
Device menu).
The Web RCS interface should load into your web browser.
CONNECTION ESTABLISHED
Once the connection has been established, the Web RCS interface will load into your web browser. The 2
icons at the bottom right corner of the Web RCS interface indicate that the Web RCS software is ready to
be used:
• V701: Turns green when connected.
• Sync OK: Turns green when the Web RCS has finished synchronizing.
If you have trouble synchronizing, clear the cache and refresh the web-page (CTRL+F5 shortcut on most
browsers).