7.2 Common Commands
7-5
7
Remote Commands
:SYSTem:CFUNction <function>
Parameter <function>=<CHARACTER PROGRAM DATA>
OFF Off
ASE32 Auto Search (MU183040A/41A/40B/41B, MP1862A)
EMAR32 Eye Margin measurement (MU183040A/41A/40B/41B,
MP1862A)
EDI32 Eye Diagram measurement (MU183040A/41A/40B/41B,
MP1862A)
BTUB32 Bathtub measurement (MU183040A/41A/40B/41B,
MP1862A)
AADJ32 Auto Adjust (MU183040A/41A/40B/41B)
QAN32 Q measurement (MU183040A/41A/40B/41B)
Note:
If set to Off, the previous interface settings are restored.
Function Sets the auto measurement function you want to operate.
Example To set the common function you want to operate to Auto Search (32G/64G):
> :SYSTem:CFUNction ASE32
Compatibility Incompatible with existing models.
:SYSTem:CFUNction?
Response <function>=<CHARACTER RESPONSE DATA>
OFF Off
ASE32 Auto Search (MU183040A/41A/40B/41B, MP1862A)
EMAR32 Eye Margin measurement (MU183040A/41A/40B/41B,
MP1862A)
EDI32 Eye Diagram measurement (MU183040A/41A/40B/41B,
MP1862A)
BTUB32 Bathtub measurement (MU183040A/41A/40B/41B,
MP1862A)
AADJ32 Auto Adjust (MU183040A/41A/40B/41B)
QAN32 Q measurement (MU183040A/41A/40B/41B)
Function Queries the auto measurement function being operated.
Example > :SYSTem:CFUNction?
< ASE32
Compatibility Incompatible with existing models.