7.3 64G DEMUX Commands
7-25
7
Remote Commands
:DEMux:CLOCk:SELection <sel>
Parameter <sel>=<CHARACTER PROGRAM DATA>
EXTernal External Clock
Function Sets clock input type.
Example To set Data Interface clock input type to external clock:
> :DEMux:CLOCk:SELection EXTernal
Compatibility Compatible with MU182040A and MU182041A.
:DEMux:CLOCk:SELection?
Response <sel>=<CHARACTER RESPONSE DATA>
EXT External Clock
Example To query Data Interface clock input type:
> :DEMux:CLOCk:SELection?
< EXT
Compatibility Compatible with MU182040A and MU182041A.
:DEMux:CLOCk:UIDelay<numeric>
Parameter <numeric>=<DECIMAL NUMERIC PROGRAM DATA>
–1000 to 1000 –1000 to 1000mUI/4mUI Step
Function Sets clock input phase variation in mUI units.
Example To set Data Interface clock phase variation to –1000 mUI:
> :DEMux:CLOCk:UIDelay -1000
Compatibility Compatible with MU182040A and MU182041A.
:DEMux:CLOCk:UIDelay?
Parameter <interface>=<DECIMAL NUMERIC PROGRAM DATA>
Response <numeric>=<NR1 NUMERIC RESPONSE DATA>
Function Queries clock input phase variation in mUI units.
Example To query Data Interface clock phase variation in mUI units:
> :DEMux:CLOCk:UIDelay?
< -1000
Compatibility Compatible with MU182040A and MU182041A.