Chapter 7 Remote Commands
7-28
:DEMux:CLOCk:JINPut <boolean>
Parameter <boolean>=<BOOLEAN PROGRAM DATA>
0 or OFF Jitter Input OFF
1 or ON Jitter Input ON
Function Sets Jitter Input ON/OFF.
Example To set Data Interface Jitter Input to ON:
> :DEMux:Clock:JINPut ON
Compatibility Compatible with MU182040A and MU182041A.
:DEMux:CLOCk:JINPut?
Response <numeric>=<NR1 NUMERIC RESPONSE DATA>
0 Jitter Input OFF
1 Jitter Input ON
Function Queries Jitter Input ON/OFF.
Example To query Data Interface Jitter Input ON/OFF:
> :DEMux:CLOCk:JINPut?
< 1
Compatibility Compatible with MU182040A and MU182041A.
:DEMux:CLOCk:BAND <sw>
Parameter <sw>=<CHARACTER PROGRAM DATA>
HALFrate Half Clock Rate
QUATerrate Quarter Clock Rate
EIGHthrate 1/8 Clock Rate
Function Switches Clock Input Band Switch.
Example To switch Data Interface Clock Input Band Switch to Half:
> :DEMux:Clock:BAND HALF
Compatibility Incompatible with existing models.
:DEMux:CLOCk:BAND?
Response <numeric>=<NR1 NUMERIC RESPONSE DATA>
HALFrate Half Clock Rate
QUATerrate Quarter Clock Rate
EIGHthrate 1/8 Clock Rate
Function Queries Clock Input Band Switch.
Example To query Data Interface Clock Input Band Switch:
> :DEMux:CLOCk:BAND?
< HALF
Compatibility Incompatible with existing models.