Chapter 7 Remote Commands
7-52
7.4.2.2 File menu setting commands
Table 7.4.2.2-1 File Menu Setting Commands
No. Item Command
[1] Open :SYSTem:MMEMory:MARGin:RECall
[2] Save :SYSTem:MMEMory:MARGin:STORe
:SYSTem:MMEMory:MARGin:RECall <file_name>
Parameter <file_name>=<STRING PROGRAM DATA>
"<drv>:\[<dir>]<file>"
<drv> = C,D,E,F
<dir>=<dir1>\<dir2>\...(Omitted for the root directory)
<file> = File Name
Function Opens the Eye Margin measurement result data.
Example > :SYSTem:MMEMory:MARGin:RECall "C:\Test\example"
Compatibility Incompatible with existing models.
:SYSTem:MMEMory:MARGin:STORe <file_name>,<file_type>
Parameter <file_name>=<STRING PROGRAM DATA>
"<drv>:\[<dir>]<file>"
<drv> = C,D,E,F
<dir>=<dir1>\<dir2>\...(Omitted for the root directory)
<file> = File Name
<file_type>=<CHARACTER PROGRAM DATA>
BIN Binary file
CSV CSV file
TXT Text file
Function Saves the Eye Margin measurement result data.
Note:
The settings will not be read from the saved file if the file name is
changed.
Example To save the Eye Margin measurement result data by specifying the save
destination, file name, and file format:
> :SYSTem:MMEMory:MARGin:STORe "C:\Test\example",TXT
Compatibility Incompatible with existing models.