Chapter 7 Remote Commands
7-100
:DISPlay:RESult:BATHtub:ITEM <mode>
Parameter <mode>=<CHARACTER PROGRAM DATA>
PBER Phase vs BER (Y axis Log)
PLNBer Phase vs BER (Y axis Log (–Ln))
HISTogram Histogram
Function Sets the item to be displayed in the graph during Bathtub measurement.
Example To set the display item to Histogram:
> :DISPlay:RESult:BATHtub:ITEM HISTogram
Compatibility Incompatible with existing models.
:DISPlay:RESult:BATHtub:ITEM?
Response <mode>=<CHARACTER RESPONSE DATA>
PBER, PLNB, HIST
Function Queries the item to be displayed in the graph during Bathtub measurement.
Example > :DISPlay:RESult:BATHtub:ITEM?
< HIST
Compatibility Incompatible with existing models.
:DISPlay:RESult:BATHtub:MNUMber <numeric>
Parameter <numeric>=<DECIMAL PROGRAM DATA>
1 to 1000 Measurement number 1 to 1000 (number of
measurements during repeat measurement)
Function Selects the measurement number for which the Bathtub measurement
result is displayed in a graph.
Example To select the measurement number 100 to display the graph:
> :DISPlay:RESult:BATHtub:MNUMber 100
Compatibility Incompatible with existing models.
:DISPlay:RESult:BATHtub:MNUMber?
Response <numeric>=<NR1 NUMERIC RESPONSE DATA>
Function Queries the measurement number for which the Bathtub measurement
result is displayed in a graph.
Example > :DISPlay:RESult:BATHtub:MNUMber?
< 100
Compatibility Incompatible with existing models.