VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 100 of 308
sue: 03 complete, approved
7.3.2 PTT Button Cough Timeout Configuration
The cough timeout is the time length the PTT button may be released before the route is closed down. When
this is enabled, the audio path is muted immediately when the PTT button is released, allowing the operator
to cough without it being broadcast. If the PTT button is then re-pressed within the cough time, the
announcement will continue as normal.
In order to configure the cough timeout proceed as follows.
1. Select ConfigurationÆSystemÆRouterÆInputsÆMic/Line.
2. Scroll the Mic/Line input list and select the required input:
[I/P #01 – MIC/LINE 01]
Default value: input 1
Possible inputs: 01 to 04 for VAR4
01 to 12 for VAR12
01 to 20 for VAR20
Note: The input name is shown on the right side of the display. The input name above is the Mic/Line
input 1 default name, however this may have been changed according to each site’s
configuration.
3. The configured Mic/Line type is displayed.
The input type may be changed, as described in Section “7.1 Mic/Line Input Type Configuration”.
4. Press the SELECT key to display the next sub-menu.
5. Move to, and select the Buttons menu item.
[Buttons] Audio Ctrl Name
Note: The ‘Buttons’ menu item is only available for Paging and Zoned Fire Microphones.
6. Move to, and select the Cough menu item.
PTT Zoning Switches [Cough]
7. Scroll the cough timeouts until the required value is displayed:
[Cough (10th Sec) 0]
Default value: ‘0’
Possible values: 0 to 50. Multiply by 0.1 to have the time in seconds.
Note: The rotary encoder can be used to adjust the cough time in 0.1s increments.
8. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.