VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 271 of 308
4. Move to, and select the B2 menu item:
sue: 03 complete, approved
18.4.4 Battery Voltage Feeding Slots 3 and 4
The battery voltage feeding slots 3 and 4 in a mainframe can be displayed, as described in the following
steps.
1. Select TestsÆStatus.
2. Scroll and select a mainframe from the list:
[Frame#nn - ]
Mainframe: 01 to 63
Note: Only configured mainframes are displayed.
The mainframe description will be shown on the right side, if defined.
3. Move to, and select the Measured menu item.
DIP = 000000 [Measured] Slot#1
BAT B1 [B2] DC1 DC2 AUX Temp
5. The battery voltage is displayed:
[Battery Monitor 2 Volts= 21.3]
6. Return to the parent menu by pressing the SELECT key, or the BACK key.
18.4.5 Mains Derived DC Supply Feeding Slots 1 and 2
The mains derived DC supply voltage feeding slots 1 and 2 in a mainframe can be displayed, as described in
the following steps.
1. Select TestsÆStatus.
2. Scroll and select a mainframe from the list:
[Frame#nn - ]
Mainframe: 01 to 63
Note: Only configured mainframes are displayed.
The mainframe description will be shown on the right side, if defined.
3. Move to, and select the Measured menu item.
DIP = 000000 [Measured] Slot#1
4. Move to, and select the DC1 menu item:
BAT B1 B2 [DC1] DC2 AUX Temp
5. The DC supply voltage is displayed:
[DC Monitor 1 Volts= 21.4]
6. Return to the parent menu by pressing the SELECT key, or the BACK key.