VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 234 of 308
sue: 03 complete, approved
5. Move to, and select the Ans menu item:
UNUSED Selector Volume Fault [Ans]
Other options available:
• Unused
Select this option if the analogue input is not connected.
See Section “16.2.1 Configuring an Analogue Input as Unused”.
• Selector
Assign the selected analogue input as Programme Selector.
See Section “16.2.2 Configuring an Analogue Input as Programme Selector”.
• Volume
Assign the selected analogue input as Volume Control.
See Section “16.2.3 Configuring an Analogue Input as Volume Control”
• Fault
Assign the selected analogue input as Fault Input.
See Section “16.2.4 Configuring an Analogue Input as Fault Input”.
6. Move to, and scroll the output list until the required output is displayed in the left field:
[OUTPUT 01] Not Selected
Default values: output 1 name
Outputs: 4 output for VAR4
12 output for VAR12
20 output for VAR20
Note: The output given above is the output 1 default name, however this may have been changed
according to each site’s configuration.
7. Move to, and toggle to the required selection option in the right field:
OUTPUT 01 [Not Selected]
• [Not Selected]
The output is not controlled by the ANS Sensor.
• [Selected]
The output gain is controlled by the ANS Sensor, and modified in response to changes in ambient
noise level.
Default value: ‘Not-Selected’
8. Repeat steps 6 to 7 to configure each output.
9. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.