V9.7 01/05/20 UD0011 Page 131 of 177
This Document is uncontrolled when printed unless over stamped “CONTROLLED DOCUMENT"
16. TAMPER SWITCHES
There are 3 tamper switches fitted to Traka Touch Systems that, when activated, will display a message on the touch
screen and log an event. The message will be displayed in the orange bar at the top of the screen. The system will also
sound an alarm whilst the switch is activated.
Tamper Switch 1 fitted to the rear of the Control Panel and is activated when the Control Panel is opened.
This will return a ‘Panel Opened’ event and a ‘Panel Closed’ event once the Control Panel has been closed.
Tamper Switch 2 fitted behind the Receptor Strip Frame on an S-Series and is activated when the Receptor
Panel is opened. This will return a ‘Receptor Panel Open’ event and a ‘Receptor Panel Closed’ event once the
Receptor Panel has been closed.
Tamper Switch 3 fitted to the rear of the cabinet and is activated when the system is removed from the
wall. This will return a ‘Wall Tamper’ event and a ‘Wall Tamper End’ event when the system is back against the
wall.