Avaya 4000 Series - Configuring SNMPv3 trap receiver

Avaya 4000 Series
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Procedure
1. Use the snmp-server community notify-view acli command to configure
the community string.
2. When prompted, enter and confirm the community string.
3. Use the snmp-server host <IP address> v2c <string> command to
configure the community string.
Variable Definitions
Variable Definition
IP address IPv4 address of the server host
string The community string that has been defined
for sending SNMPv2c traps
Configuring SNMPv3 trap receiver
About this task
Use the procedure in this section to configure an SNMPv3 trap receiver.
Procedure
1. Use the snmp-server user trapuser notify-view acli command to
configure the trap user.
2. Use the snmp-server host <IP address> v3 no-auth <user> command
to configure the community string.
Variable Definitions
Variable
Definition
IP address IPv4 address of the server host
user The user that has been defined for sending
SNMPv3 traps
Troubleshooting RSTP SNMP traps
214 Troubleshooting Avaya ERS 4000 Series April 2014