Sys capability: O-Other; R-Repeater; B-Bridge; W-WLAN accesspoint; r-Router;
T-Telephone; D-DOCSIS cable device; S-Station only.
(config)#sho lldp port 7 neighbor dot3
-------------------------------------------------------------------------------
LLDP neighbor
-------------------------------------------------------------------------------
Port: 7 Index: 4 Time: 0 days, 00:53:04
ChassisId: MAC address 00:10:18:82:0b:bd
PortId: MAC address 00:10:18:82:0b:bf
PSE MDI power: not supported/disabled Port class: PD
PSE power pair: spare/not controllable Power class: 4
PD: Type: Type 2 PD Source: PSE Priority: Low
PD: PD requested power: 23.0 Watts
PD: PSE allocated power: 23.0 Watts
-------------------------------------------------------------------------------
Sys capability: O-Other; R-Repeater; B-Bridge; W-WLAN accesspoint; r-Router;
T-Telephone; D-DOCSIS cable device; S-Station only.
Total neighbors: 3
(config)# show poe-main-status
PoE Main Status - Stand-alone
--------------------------------------------------
Available DTE Power : 855 Watts
DTE Power Status : Normal
DTE Power Consumption : 5 Watts
DTE Power Usage Threshold : 80 %
PD Detect Type : 802.3at and Legacy
Power Source Present : AC Only
Primary Power Status : Present and operational
Redundant Power Status : Not Present
IP Phone Priority : N/A
IP Phone Power Limit : N/A
(config)#show poe-port-status 7
Admin Current Limit
Port Status Status Classification (Watts) Priority
---- ------- ----------------- -------------- ------- --------
7 Enable Delivering Power 4 32 Low
show poe-power-measurement 21
Port Volt(V) Current(mA) Power(Watt)
---- ------- ----------- ---------------
21 53.7 108 5.800
Run scripts
According to Avaya best practices for converged solutions, you can use the scripts to configure
the parameters for an Avaya stackable Ethernet Switch. The scripts can be executed in a
default or verbose mode. In this release, run scripts are available in non-verbose and verbose
mode for IP Office, and verbose mode for Link Layer Discovery Protocol (LLDP) and Auto
Detect Auto Configuration (ADAC).
Follow the steps in Configuring Systems on Avaya Ethernet Routing Switch 4000 Series
NN47205-500.
Run scripts
Troubleshooting Avaya ERS 4000 Series April 2014 163