D-channel monitoring on the TMDI card
T
able 46: D-channel monitoring commands
Command Action
DIS TMDI x MSGI Disable monitoring of incoming D-channel messages
on
TMDI card x.
DIS TMDI x MSGO Disable monitoring of outgoing D-channel messages
on TMDI card x.
ENL TMDI x ALL MSGI Enable monitoring of incoming D-channel messages
on TMDI card x.
ENL TMDI x ALL MSGO Enable monitoring of outgoing D-channel messages
on link TMDI card x.
ENL TMDI x ALL DBG Enable debugging on TMDI card x.
DIS TMDI x DBG Disable debugging on TMDI card x.
PSWD TMDI Print passwords.
STAT TMDI x MON Print monitoring commands for TMDI card x.
D-channel status and error conditions are reported as DCH messages. These messages can
be found in the Avaya Software Input Output Reference - System Messages
(NN43001-712).
Table 47: Clock controller commands (LD 60)
Command Action
DIS CC N Disable clock controller N.
ENL CC N Enable clock controller N.
SSCK N Status of clock controller N.
TRCK XXXX N Set clock controller tracking.
Where xxxx =
PCK =
Track primary clock reference source.
SCLK = Track secondary clock reference source.
FRUN = Free run mode.
NTAK09 DTI/PRI power on self-test
When power is applied to the NT
AK09 DTI/PRI circuit card, the card performs a self-test. The
LEDs directly associated with the NTAK09 circuit card are DIS, ACT, RED, YEL, and LBK. The
DTI/PRI maintenance tools
ISDN Primary Rate Interface Maintenance November 2011 107