Figure 2: PRI link-diagnostic and remote loopback tests
PRI error detection
Bit error rate
Bit-error-rate monitoring detects errors in transmission. See Figure 3: Bipolar violations on
page 47.
Bipolar violation (BPV) tracking
In a bipolar pulse stream, pulses alternate in polarity
. A bipolar violation has occurred if, after
transmission, two pulses of the same polarity are received in succession (this could be caused
by an electrical disturbance such as noise).