PRI commands (LD 60)
Primary Rate Interface (PRI) diagnostic commands are used to maintain both PRI and clock-
controller operation. See Table 10: PRI card and channel commands in LD 60 on page
40
for a list of the PRI card and channel commands in LD 60. The commands are organized as
follows:
• PRI card and channel commands
• Alarm and counter commands
• Test commands
Table 10: PRI card and channel commands in LD 60
Command Description
DISI L PRI loop L is disabled only when all the channels are idle. The network
and PRI cards are then disabled and status LEDs are lit. Channel status
is set to busy
. Enter END to abort.
DISL L Disables network and PRI circuit packs of loop L. Active calls are
automatically disconnected by on-hook simulation. All channels are
disabled and status LEDs are lit.
DSCH L CH All channels of loop L are disabled.
ENCH L CH All channels of loop L are enabled.
ENLL L Enables PRI loop L. Channel CH of PRI loop L is enabled. The channel
is placed into the idle state and made available for calls.
STAT Prints the status of all digital loops.
STAT loop Get status of digital loop. Sample output:
AAA TRK LOOP x - BBBB SERVICE RESTORE: YES/NO YEL ALM
PROCESS: YES/NO ALARM STATUS: NO ALARM/RED(local) ALARM
Where: AAA may be:
DTI
DTI2
PRI
PRI
TIE
DID
DTI LINK (DTI link loop = DLI)
Where: BBBB may be:
DSBL = Hardware of specified digital loop is disabled
ENBL = Hardware of specified digital loop is enabled
RLBK = Hardware of specified digital loop is in remote loop back mode
DISI PENDING = DSI command is in progress
TRACKING = System clock is tracked to this loop
Primary Rate Interface maintenance
40 ISDN Primary Rate Interface Maintenance November 2011
Comments? infodev@avaya.com