Command Action
RCNT (L) Reset alarm counters and clear alarms.
SLFT (L) Do 2.0 Mb PRI self-test (2.0 Mb PRI must be disabled first).
STAT (L) List 2.0 Mb PRI status.
RLBK L (C) Enable remote loopback.
DLBK L (C) Disable remote loopback.
RMST L (C) Perform remote loopback.
PRI status and error conditions are reported in the Primary Rate Interface messages in A
vaya
Software Input Output Reference - System Messages (NN43001-712).
DCHI commands
D-channel commands are found in LD 96. Table 80: DCHI commands on page 159 provides
a quick-reference list of D-channel commands.
Table 80: DCHI commands
Command Action
DIS DCHI N Disable DCHI port N.
ENL DCHI N Enable DCHI port N.
EST DCH N Establish D-channel N.
PLOG DCHI N Print D-channel statistics log N.
RLS DCH N Release D-channel N.
SDCH DCH N Release a D-channel and switch D-channels.
RST DCH N Reset D-channel N.
STAT DCH (N) Print D-channel status (link status).
TEST 100/101 DCH tests.
STAT SERV Print the current service and service acknowledge message for
DCHI N.
ENL SERV N Enable service messages for DCHI N.
DIS SERV N Disable service messages for DCHI N.
D-channel status and error conditions are reported as DCH messages. These messages can
be found in the Avaya Software Input Output Reference - Maintenance (NN43001-711).
System PRI maintenance tools
ISDN Primary Rate Interface Maintenance November 2011 159

Table of Contents

Other manuals for Avaya CS 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avaya CS 1000 and is the answer not in the manual?

Avaya CS 1000 Specifications

General IconGeneral
BrandAvaya
ModelCS 1000
CategoryServer
LanguageEnglish

Related product manuals