Chapter 8: Clock controller maintenance
Contents
This section contains information on the following topics:
Clock operation on page
77
Tracking mode on page 77
Free run (non-tracking) mode on page
78
Reference clock errors on page 78
Automatic clock recovery on page 79
Automatic clock switching on page 79
Clock controller commands (LD 60) on page 80
Replace the clock controller on page 81
Task summary list on page
81
Set switches on page
82
Clock controller cabling on page 83
Clock operation
Tracking mode
In tracking mode, the PRI loop supplies an external clock reference to a clock controller (CC).
See Figure 14: Clock controller primary and secondary tracking on page 78.
Two PRI loops
can operate in tracking mode, with one defined as the primary reference source for clock
synchronization, the other defined as the secondary reference source. The secondary
reference acts as a backup to the primary reference.