8
No. Item code Item
Factory default
User Settings and descriptions
settings
settings
1 P-1
Proportional band (PID group 1)
100.0 0.0 to 1000.0%
(0.0: On-off control)
2 I-1 Integral time (PID group 1) 0 0 to 3600sec
(0: no integral operation)
3 d-1 Derivative time (PID group 1) 0 0 to 1200sec
(0: no derivative operation)
4 rE-1 Manual reset (PID group 1) 50.0 0.0 to 100.0%
5 oL-1
Manipulated variable lower limit (Output limiter group 1)
0.0 –5.0 to manipulated variable upper limit %
6 oH-1
Manipulated variable upper limit (Output limiter group 1)
100.0 Manipulated variable lower limit to +105.0%
7 P-2
Proportional band (PID group 2)
100.0 0.0 to 1000.0%
(0.0: On-off control)
8 I-2 Integral time (PID group 2) 0 0 to 3600sec
(0: no integral operation)
9 d-2 Derivative time (PID group 2) 0 0 to 1200sec
(0: no derivative operation)
10 rE-2 Manual reset (PID group 2) 50.0 0.0 to 100.0%
11 oL-2
Manipulated variable lower limit (Output limiter group 2)
0.0 –5.0 to manipulated variable upper limit %
12 oH-2
Manipulated variable upper limit (Output limiter group 2)
100.0 Manipulated variable lower limit to +105.0%
13 P-3
Proportional band (PID group 3)
100.0 0.0 to 1000.0%
(0.0: On-off control)
14 I-3 Integral time (PID group 3) 0 0 to 3600sec
(0: no integral operation)
15 d-3 Derivative time (PID group 3) 0 0 to 1200sec
(0: no derivative operation)
16 rE-3 Manual reset (PID group 3) 50.0 0.0 to 100.0%
17 oL-3
Manipulated variable lower limit (Output limiter group 3)
0.0 –5.0 to manipulated variable upper limit %
18 oH-3
Manipulated variable upper limit (Output limiter group 3)
100.0 Manipulated variable lower limit to +105.0%
19 P-4
Proportional band (PID group 4)
100.0 0.0 to 1000.0%
(0.0: On-off control)
20 I-4 Integral time (PID group 4) 0 0 to 3600sec
(0: no integral operation)
21 d-4 Derivative time (PID group 4) 0 0 to 1200sec
(0: no derivative operation)
22 rE-4 Manual reset (PID group 4) 50.0 0.0 to 100.0%
23 oL-4
Manipulated variable lower limit (Output limiter group 4)
0.0 –5.0 to manipulated variable upper limit %
24 oH-4
Manipulated variable upper limit (Output limiter group 4)
100.0 Manipulated variable lower limit to +105.0%
25 P-5
Proportional band (PID group 5)
100.0 0.0 to 1000.0%
(0.0: On-off control)
26 I-5 Integral time (PID group 5) 0 0 to 3600sec
(0: no integral operation)
27 d-5 Derivative time (PID group 5) 0 0 to 1200sec
(0: no derivative operation)
28 rE-5 Manual reset (PID group 5) 50.0 0.0 to 100.0%
29 oL-5
Manipulated variable lower limit (Output limiter group 5)
0.0 –5.0 to manipulated variable upper limit %
30 oH-5
Manipulated variable upper limit (Output limiter group 5)
100.0 Manipulated variable lower limit to +105.0%
31 P-6
Proportional band (PID group 6)
100.0 0.0 to 1000.0%
(0.0: On-off control)
32 I-6 Integral time (PID group 6) 0 0 to 3600sec
(0: no integral operation)
33 d-6 Derivative time (PID group 6) 0 0 to 1200sec
(0: no derivative operation)
34 rE-6 Manual reset (PID group 6) 50.0 0.0 to 100.0%
35 oL-6
Manipulated variable lower limit (Output limiter group 6)
0.0 –5.0 to manipulated variable upper limit %
36 oH-6
Manipulated variable upper limit (Output limiter group 6)
100.0 Manipulated variable lower limit to +105.0%