EasyManua.ls Logo

Baldor Flex+DriveII - Regeneration

Baldor Flex+DriveII
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications 7-5MN1902
7.1.5 Regeneration
115VAC (Catalog number FDH1.../FPH1...) Unit 2.5A 5A 7.5A
Switching threshold VDC on: 188- 195, off: 183-188
Nominal power (10% power cycle) kW 0.25
Peak power (10% power cycle) kW 2.7
Maximum regeneration
switching current
A
RMS
10
Maximum load inductance ìH 100
*Note: 2.5A models (FDH1A02... and FPH1A02...) contain an internal 175, 20W resistor.
5A models (FDH1A05... and FPH1A05...) contain an internal 90, 40W resistor .
230VAC (Catalog number FDH2.../FPH2...) Unit 2.5A 5A 7.5A
Switching threshold VDC on: 373- 383, off: 362-372
Nominal power (10% power cycle) kW 0.25
Peak power (10% power cycle) kW 2.7
Maximum regeneration
switching current
A
RMS
10
Maximum load inductance ìH 100
*Note: 2.5A models (FDH2A02... and FPH2A02...) contain an internal 175, 20W resistor.
5A models (FDH2A05... and FPH2A05...) contain an internal 90, 40W resistor .
230VAC three-phase models
(Catalog number FDH2A15.../FPH2A15...)
Unit 15A
Switching threshold VDC on: 376, of f: 365
Nominal power (10% power cycle) kW 1.0
Peak power (10% power cycle) kW 15
Maximum regeneration
switching current
A
RMS
40
Maximum load inductance ìH 100