7-8 Specifications MN1902
7.1.9 Relay output (X3)
All models Unit All models
Contac ts Normally closed
Cont act rating (resistive) 1A @ 30VDC
or
0.5A @ 125VAC
Maximum carrying current A 2
Maximum switching power 62.5AV, 30W
Maximum switching voltage 250VAC, 220VDC
Maxim um switching current A 2
Capacitance
(between open contacts, at 1kHz)
pF 0.5
Update interval Immediate
7.1.10 Serial RS232 interface (X6)
All models Unit All models
Signal RS232, non-isolated CTS/RTS
Bit rate Baud 9600, 19200, 38400, 57600
7.1.11 Serial RS485 interface (X6)
All models Unit All models
Signal 4- wire RS485, non-isolated
Bit rate Baud 9600, 19200
7.1.12 Encoder output (simulated) (X7)
All models Unit All models
Signal RS422
Resolution
with resolver input on X8
with encoder input on X8
with absolute encoder input on X8
ppr Simulated 512 / 1024 / 2048* / 4096*
(*Only available if resolver input is set to
simulate a 4096ppr source.
Output is a copy of the input on X8
Output ppr equals the number of Sin/Cos
cycles per revolution of the input.
See section 4.4.1.

Table of Contents

Other manuals for Baldor Flex+DriveII

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baldor Flex+DriveII and is the answer not in the manual?

Baldor Flex+DriveII Specifications

General IconGeneral
BrandBaldor
ModelFlex+DriveII
CategoryServo Drives
LanguageEnglish

Related product manuals