7. Advanced
4. Use or to select CLO
5. Press to pull down the menu
6. Use or to select Target
7. Press to pull down the menu
8. Use or to select Normal Mode ...
Image 7-111
9. Press ENTER
A dialog box is displayed
Image 7-112
10.Use or , the numeric keys on the remote, or the keypad to change the target value.
7.7.4.3 Linked CLO
Introduction
Projectors in a multichannel setup use the same kind of lamp. These lamps may slightly differ in their output and will in certain cases
have different runtimes, this will result in a difference in light output between the projectors.
By using the constant light output in a Master/Slave conguration, it is possible to track and maintain the brightness levels of the
projectors, the projectors will deliver an equal light output.
In a multichannel setup (max. 10 projectors ) it is poss
ible to link the CLO values of all projectors. One projector will act as master,
all slave projectors will track and maintain the CLO setting of this master projector.
Following CLO Settings are available:
MASTER Master projector to control the CLO in a chain of projectors, the target value in the Master projector will be
the target value for all projectors set as slave and which are listed in “Linked Projectors”
SLAVE Follows the master projector to adjust the CLO
OFF no linking ( note : if CLO mode is ON, it will applied on the projector itself)
Table 7 - 6
CLO Settings
The linked projectors must be dened by their IP addresses or Hostnames. This is done in the Linked projec-
tors menu in the Installation menu.
114 R59770286 NW-12 07/09/2009