Glossary
Operator Manual for the Baxter ExactaMix 2400 Compounder
53007410 Rev. C Page 213
Term
Definition
initial setup
The placement and assembly of the product components at the
customer facility by Baxter personnel.
inlet
A sterile tube with a spike or Luer end attached. The spike or Luer end
attaches to a source container, and the other end attaches to a port on
the valve set.
intermediate flush
A delivery of fluid that comes just before the final flush as part of an
enhanced flush. The fluid used for this flush is always the Universal
Ingredient, and it is pumped in two deliveries of 50 mL each.
large-volume delivery
See macro ingredient.
load cell
The component that holds the destination bag, weighs the compounded
solution and reports the measurement to the software. It mounts to the
base plate.
macro ingredient
A generic term used to describe an ingredient that uses a large-bore inlet
and is delivered in volumes equal to or greater than 5 mL.
main module
The component that contains the valve actuators, occlusion detector,
bubble detector, pump chamber and power supply. It mounts to the
base plate.
maintenance
The act of performing scheduled or expected work on the compounder.
It does not include repairs or corrections due to product failure.
manage
The act of creating, modifying, saving or deleting information within the
software.
manual addition
A product that is added to the compounded solution manually, after
compounding has finished.
message
Small on-screen window or other text that provides information or
instructions, but does not allow you to enter information. Pay attention
to the text, because some messages may include critical information.
micro ingredient
A generic term used to describe an ingredient that uses a micro inlet and
is delivered in volumes less than 5 mL.
National Drug Code (NDC)
A unique, three-segment number used in the United States to identify
drug products used by humans.
occlusion
A blockage in the fluid pathway.
OEM
Original Equipment Manufacturer i.e Baxter Healthcare
outlet tube
The section of tube on the discharge side of the valve set. It connects the
valve set to the destination bag.
.PAT file
A file, created in the order-entry software, which contains the patient
information and formula.
.FRM file
An encrypted file, created in the order-entry software, which contains
the patient information and formula.
2D Formula Barcode Label
A label, printed in the order-entry software, which contains the patient
information and formula along with the 2D Barcode.
patient
The recipient of the finished solution.
permissions
The privileges granted to groups of users to allow them to perform
specific functions.
port
The interface between the valve set and the inlets for source containers.
prime
To pump a small volume of an ingredient through an inlet, to remove air
bubbles from the inlet and prepare it for compounding the solution.
privileges
See permissions.
product
An ingredient in a particular container size and type from a specific
manufacturer. Several products can be associated with one ingredient.
pump
A peristaltic device used to push fluid through the outlet tube.
pump module
See main module.