EasyManuals Logo

BEKA BEKA-MAX PICO-troniX1 User Manual

BEKA BEKA-MAX PICO-troniX1
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
© BEKA 201 !9 All rights reserved
BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
39
Signalindicators:
The followingmessages are displayed bythe integrated control unitby the redand green LED inthe inspection window of
theprotective housing(see chapter13.2 „Signalindicators ofthe integratedcontrolunit PICO-tronic"):
· Operationalcapability
· Lubricationin process
· Nextpulse ofthe cycleduration hasnot beenreached withinthepulse monitoringtime ofcycle duration
· Set number of pulses of the lubrication duration has not been reached within the pulse monitoring time of lubrication
duration
· Setnumber ofpump revolutionshas notbeen reachedwithin themonitoring timeof revolutions
· Reservoirempty (onlyfor deviceswith follow-uppiston)
· Systempressure toohigh
· Pressuredrop inline system(line break)
· Cyclelocked
· Lubricationdeficit (lubricationcannot befinished duringthe lubricationduration)
· CPU/ memorydefective
· Trial lubricationin process
Operationaldatabase:
Theintegrated controlunit hasan operationaldatabase inwhich thefollowingvalues arestored:
· Dataof thecontrol unit(type, version,serial number, manufacturingdate)
· Currentsettings (operationalmode, cycleduration, lubricationduration, monitoringtimes)
· Statistical values (operating hours, operating time of the device, number of the intermediate lubrications, number of
thelevel errors,number ofthe pulseerrors, numberof therevolutionerrors, numberof theoverall diagnosesetc.)
· Dateand timeof thelast diagnosis
· Errorlog ofthe last100 errorswith indicationof thetype oferror aswell asthe indicationof thetime and date
· Eventlog ofthe last100 settingchanges withindication oftimeand date
The operational mode and the setting range of the cycle and lubrication duration and the setting of
the monitoring times can be changed at any time using the diagnosis software (withBEKA-DiSys
thecurrent versionavailable at ).www.beka-lube.de
Notice!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BEKA BEKA-MAX PICO-troniX1 and is the answer not in the manual?

BEKA BEKA-MAX PICO-troniX1 Specifications

General IconGeneral
BrandBEKA
ModelBEKA-MAX PICO-troniX1
CategoryWater Pump
LanguageEnglish

Related product manuals