4
1. Technical data
General:
Delivery rate per stroke and outlet: . . . . . . . . . . . . . . depending on pump element (see chapter 8.4 „Pump elements“)
No. of outlets: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pump elements PE-5 to PE-50: . . . . . . . . . . . . . . . . max. 8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pump elements PE-60 F to PE-170 F:. . . . . . . . . . . max. 2
Pressure connection:. . . . . . . . . . . . . . . . . . . . . . . . . Ø4 mm, Ø6 mm or thread M10x1 (multi-line lubrication systems)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ø6 mm, Ø8 mm or thread G1/4" (progressive lubrication systems)
Lubricant: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . greases up to NLGI cl. 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (greases with solids content on request)
Operating pressure:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 200 bar (multi-line lubrication systems)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 300 bar (progressive lubrication systems)
Pressure limiting valve: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . set to 290 bar (progressive lubrication systems)
Operating temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35°C up to +70°C
Transport and storage temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40°C up to +70°C
Reservoir material: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . plastic, transparent
Reservoir size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,5 l
Effective volume:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,2 l
Installation position: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . optional (version with follow-up piston)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . reservoir in a vertically upright position (version with agitator blade)
Level monitoring:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . with, installed in pump body (version with follow-up piston)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . without (version with agitator blade)
Rotational direction of the agitator blade:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . clockwise
Degree of protection:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 65
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 4,8 kg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (without pump element, without grease filling, depending on equipment)
Motor:
Supply voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 or 24 V DC
Current load max.:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,3 A at 12 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,3 A at 24 V
Pump speed:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 r.p.m
Integrated control unit:
Supply voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 to 60 V
Current load max.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,0 A
Output for signal lamp:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,4 A
Fuse (not included in device): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,3 A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (5x20) medium time lag
The issubsequently calleda .greaselubrication pumpPICO device