BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All !9 rights reserved
48
10.2 Lubricantchange
Payattention toutmost whenrefilling lubricant!cleanness
· Checkthe levelregularly andrefill cleanlubricant asnecessary,see chapter7. „Startup“.
· Change the lubricant according to the specifications of the lubricant manufacturer. Environmental influences like
increasedtemperature orpollution mayshorten theseintervals!
· Please make sure to only use lubricants that are suitable for the device as well as the lubricated machine and that
complywith therequirements ofthe particularoperating conditions.
· In case of , ensure that the lubricant corresponds to the quality of thedifferent lubricant manufacturers quality
previouslyused one!Asprecautionary measure,drain thelubricant reservoirproperlyand cleanit!
10.3 Changingthe integratedcontrol unit
A) Disconnectthe devicefrom thepower supply(pos. 1,see fig.54)and secureit againstrecommissioning.
Fig.54:
Caution!
1