9.2.2 Changingand settingthe parameters
The operationalmodes andsetting rangesof thecycle duration and lubrication durationcan bechanged atany timeusing
thediagnosis software (with thecurrent versionavailable at ).BEKA-DiSys www.beka-lube.de
When the parameters are changed, the adhesive label in the inspection window of the protective housing has to be
exchangedaccordingly.
Theadhesive labelsfor theinspection windowcan beordered asneeded.
*pulses **revolutions
Within a setting range, the lubrication duration and the cycle duration can be changed at the grid switches in the
inspectionwindow ofthe protectivehousing (seefig. 40)using aflatscrewdriver
For this, remove the frame at the inspection window of the protective housing using a flat screwdriver, loosen the four
crosspoint screwsand removethe transparentinspection window.
After setting the parameters, the inspection window and the frame have to be closed properly
again;otherwise can intothe integratedcontrol unitand can it!water enter destroy
9.2.3 Operationalmode oftime-dependent cycleduration
At the operational mode of time dependent cycle duration, the cycle duration can be set in hours or minutes, depending-
on the selected setting range. The setting range can be changed using the diagnosis software (with theBEKA-DiSys
currentversion availableat ).www.beka-lube.de
Fig.41:
Time-dependent cycle duration
Pulse-dependent cycle duration
Time-dependent lubrication duration
Pulse-dependent lubrication duration
Revolution-dependent lubrication duration
Lubrication duration
Time-dependent
cycle duration
Caution!