BAL2185_Grease_lubrication_pump_PICO_with_PICO-troniX1_-tronic_0519EN 10158410
...a product of
© BEKA 201 All !9 rights reserved
52
13. Troubleshooting
Possibly renew fuse if installed
Electrical line interrupted
Integrated control unit defective
Renew integrated control unit
Device operates, but does not
supply
Air pocket in delivery piston
Integrated control unit defective
Renew integrated control unit
No grease collar at any lube point
See malfunction „Device does not
operate“
Lubrication system blocked
See malfunction „Lubricant leakage
at pressure limiting valve“
Lubrication duration (pump operating
time) too short
Extend lubrication duration
T is shownhe error Lubrication deficit
See chapter 9.2.14 „Error
Lubrication deficit“
No grease collar at sever lubeal
points
Supply lines to secondary distributor
burst or leaky
Retighten or renew fittings
Check lubrication system / lube point
(no damage)
Lubricant leakage at pressure
limiting valve
Progressive distributor blocked
Renew affected progressive
distributor
Lubrication system blocked
Repair clogged / firm lube point
Renew pressure limiting valve
Level monitoring sends a signal
although the reservoir is filled
Level monitoring defective
Send device to BEKA for repair
Integrated control unit defective
Renew integrated control unit