Device does not switch off
although the reservoir is empty
Level monitoring defective
Send device to BEKA for repair
No level monitoring installed
(devices with agitator blade)
Fill reservoir, ventilate device
Integrated control unit defective
Renew integrated control unit
LEDs in the inspection window of
the integrated control unit flash
(see chapter 13.1.
„Signal
indicators of the integrated
control unit PICO-troniX1" or
chapter 13.2 „Signal indicators of
the integrated control unit PICO-
tronic“)
Device is temporarily out of order
Pulse error in operational mode of
pulse-dependent cycle duration
Check and possibly renew external
sensor and connected cable
Pulse error in operational mode of
pulse-dependent lubrication duration
Check and possibly renew external
sensor and connected cable
Reset error with intermediate
lubrication
No malfunction (see chapter 9.2.14
„Error “)Lubrication deficit
Trigger intermediate lubrication 1 to
2 times
Renew affected lines, retighten or
renew belonging fittings
Error System pressure too high
Check, possibly repair lubrication,
system
Reset error with intermediate
lubrication
Revolution error in operational mode
of revolution-dependent lubrication
duration
Check, possibly repair, lubrication
system or device
Reset error with intermediate
lubrication
The functions of the device
(operational mode, cycle duration
or lubrication duration) do not
correspond to the values set at
the integrated control unit
The operational mode or the setting
range of the integrated control unit
has been change , but the adhesived
label in the inspection window of the
protective housing has not been
exchanged
Establish a diagnosis with the
diagnosis software BEKA-DiSys
and adjust the settings
correspondingly or exchange the
adhesive label in the inspection
window