EasyManua.ls Logo

Bernina B 570 - Operating Voltage Functional Test

Bernina B 570
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BERNINA International AG Seestrasse 161 CH-8266 Steckborn Schweiz Seite 25 von 172
DRAFT – VERSION
3.2 Operating Voltage Functional Test
PCBA-Base voltages are displayed on the PCBA-Base via LEDs.
3.2.1 Use and functions of LEDs
What to test:
Upper LED 35V
Lower LED 5V
Target state:
lit
lit
Actual status:
not lit
not lit
Repair note:
• Check the wiring for deformation,
tears or breaks. Replace if
necessary.
• Check the connectors for
deformations. Replace if
necessary.
• Check PCBA-Power functioning.
Replace if necessary.
• Replace PCBA-Base.
• Replace PCBA-Base since this 5V are
generated directly on the PCBA-Base.

Table of Contents